Valve plate flatness for a Turkish hydraulics plant
A Turkish hydraulics manufacturer needed 0.002 mm flatness on 250 mm valve plates; a PSG-525CNC with in-process gauging brought leak-down rejects from 4.5% to under 0.8%.
Case at a Glance
The situation
Leak-down rejects on a 250 mm valve plate line were running at 4.5%. Flatness had to stay inside 0.002 mm over the port face, and the finishing pass was being run on a hydraulic machine whose table had developed a slight crown after eight years of service.
What we specified
A PSG-525CNC with closed-loop glass scales, a two-pass finish cycle, automatic dressing every eight parts and a temperature-compensated warm-up routine. The plant measures flatness on a granite plate with an electronic level every twenty parts.
Result
Flatness holds inside 0.002 mm and leak-down rejects fell below 0.8%. The plant's own conclusion: the useful change was repeatability part-to-part, not a better single-part number.